Description: A system valve is a device that regulates, directs or controls the flow of a fluid by opening, closing, or partially obstructing various passagewaysRelationshipsirrSystemValve Has irrSprinklerirrPressurizedLine Has irrSystemValveirrController Has irrSystemValveSubtypesBallButterflyConeGatePlugGlobeAngleQuick CouplerFieldsfieldnamefieldtypeprecisionscalelengthaliasisnullabledomaindefaultInstallContractorTEXT100Install ContractorNULLABLEManufacturerTEXT30ManufacturerNULLABLEirrManufacturerSerialTEXT50Serial NumberNULLABLEModelTEXT50ModelNULLABLEMotorizedSHORT5MotorizedNULLABLEBooleanZoneSHORT5ZoneNULLABLEValveFunctionTEXT30FunctionNULLABLEirrSystemValveFunctionMaterialTEXT30MaterialNULLABLEirrMaterialDiameterTEXT30DiameterNULLABLEirrDiameterElevation_mDOUBLE388Elevation (m)NULLABLEInletOutletTEXT30Inlet/Outlet NULLABLEirrSystemValveInletOutletPressureSettingSHORT5Pressure Setting(psi)NULLABLEFlowRateRangeTEXT20Flow Rate RangeNULLABLEirrFlowRateFlowRateUnitTEXT20Flow Rate UnitNULLABLEirrFlowUnitsJoinInletTEXT25Join InletNULLABLEirrJointTypeJoinOutletTEXT25Join OutletNULLABLEirrJointTypeCurrentPositionTEXT25Current PositionNULLABLEirrCurrentPositionBypassValveSHORT5Bypass ValveNULLABLEBooleanRegulationTypeTEXT20Regulation TypeNULLABLEDepthToNutDOUBLE388Depth of NutNULLABLETurnsToCloseTEXT20Turns to CloseNULLABLEirrPositionClockwiseToCloseSHORT5Clockwise To CloseNULLABLEBooleanNormallyOpenSHORT5Normally OpenNULLABLEBooleanPercentOpenSHORT5Percent OpenNULLABLEGroundTypeTEXT50Ground TypeNULLABLEDefinitionsFieldDescriptionInstall ContractorContractor Installing the system valveManufacturerDevice manufacturerSerial NumberDevice serial number ModelDevice modelMotorizedIs it motorized?ZoneIrrigation zone where the device is locatedFunctionMain function of the system valveMaterialType of material the device is made ofDiameterDiameter of openingElevation (m)Elevation of invert on metres at main sea level (msl) Inlet/Outlet Type of connection into the Inlet/OutletPressure Setting (psi)Pressure value in psiFlow Rate RangeFlow rate rangeFlow UnitsFlow unitsJoint InletJoin Inlet location in system valveJoint OutletJoin Outlet location in system valveCurrent PositionCurrent position of system valveBypass ValveHas a bypass valve?Regulation TypeRegulation typeDepth to NutDepth to nutTurns to CloseTurns to closeClockwise To CloseClockwise to close?Normally OpenIs it normally open?Percent OpenPercent openGround TypeType of soil the system valve is locatedPick ListIrriManufacturerirrMaterialirrJointTypeCodeDescriptionCodeDescriptionCodeDescriptionHunterHunterABSABSBottomBottom InletToroToroBrassBrassSideSide InletOtherOtherConcreteConcreteCopperCopperBooleanirrDiameterGlass - Filled NylonGlass - Filled NylonCodeDescriptionCodeDescriptionGlass - Filled PolypropyleneGlass - Filled Polypropylene0FALSE1/2"1/2" (13 mm)PolyethylenePolyethylene1TRUE3/4"3/4" (20 mm)PVCPVC1"1" (25 mm)Stainless SteelStainless SteelirrPosition1 1/4"1 1/4" (32 mm)SteelSteelCodeDescription1 1/2"1 1/2" (40 mm)QQuarter2"2" (50 mm)irrSystemValveInletOutletTThird2 1/2"2 1/2" (65 mm)CodeDescriptionHHalf3"3" (80 mm)ThreadedThreadedTTTwo Thirds4"4" (100 mm)SlipSlipTQThree Quarters6"6" (150 mm)Male_MaleMale x MaleFFull8"8" (200 mm)Male_BarbMale x BarbirrFlowRateirrSystemValveFunctionirrFlowUnitsCodeDescriptionCodeDescriptionCodeDescription0-90 to 9MasterMasterGPMGallons Per Minute10-9910 to 99ControlControlGPHGallons Per Hour100-499100 to 499Zone/StationZone/StationGPDGallons Per Day500-999500 to 999MainMainLPMLitres Per MinuteDrain/FlushDrain/FlushLPHLitres Per HourirrCurrentPositionStopAndDrain Stop and Drain LPDLitres Per DayCodeDescriptionIsolationIsolationUNKUnknownHHorizontalStrainer/FilterStrainer/FilterOTHOtherVVertical
Feature Type: Point
Type: FeatureLayer
Display Field: N/A
Primary Key Field: OBJECTID
Show Map Tips: False
Searchable: False
Identifiable: True
Queryable: True
Can Copy Feature: True
Snappable: True
Snapping Enabled: False
Has Attachments: False
Feature Label: AssetID: {AssetID}
Feature Description: Subtype: {SubType}
Feature Long Description: A system valve is a device that regulates, directs or controls the flow of a fluid by opening, closing, or partially obstructing various passageways
Feature Zoom Factor: N/A
Feature Zoom Scale: N/A
Feature Border Color: N/A
Feature Border Width: N/A
Feature Fill Color: N/A
Icon:
Include in Layer List: True
Include in Legend: True
Can Toggle Labels: True
Show Labels: True
Allow Symbolization: True
Draw Index: N/A
Legend URL: N/A
Style Name: N/A
Data Provider: Default
Time Zone ID: N/A
Fields:
OBJECTID (Type: Int32, Visible: False, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: True, Addressable: True)
AssetID [Asset ID] (Type: String, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: False, Addressable: True)
AssetDesc [Asset Description] (Type: String, Visible: False, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: True, Addressable: True)
LifeCycleStatus [Lifecycle Status] (Type: String, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: False, Addressable: True)
SubType [Subtype] (Type: Int32, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: True, Addressable: True)
AssetOwner [Asset Owner] (Type: Int16, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: True, Addressable: True)
AssetManager [Asset Manager] (Type: Int16, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: True, Addressable: True)
Location (Type: String, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: False, Addressable: True)
InstallDate [Install Date] (Type: DateTime, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: False, Addressable: True)
InstallContractor [Install Contractor] (Type: String, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: False, Addressable: True)
Manufacturer (Type: String, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: False, Addressable: True)
Serial (Type: String, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: False, Addressable: True)
Model (Type: String, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: False, Addressable: True)
Motorized (Type: Int16, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: True, Addressable: True)
Zone (Type: Int16, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: True, Addressable: True)
ValveFunction [Function] (Type: String, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: False, Addressable: True)
Material (Type: String, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: False, Addressable: True)
Diameter (Type: Int16, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: True, Addressable: True)
Elevation (Type: Double, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: True, Addressable: True)
InletOutlet [Inlet/Outlet ] (Type: String, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: False, Addressable: True)
PressureSetting [Pressure Setting] (Type: Int16, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: True, Addressable: True)
FlowRate [Flow Rate] (Type: Double, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: True, Addressable: True)
JoinType1 [Join Type 1] (Type: String, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: False, Addressable: True)
JoinType2 [Join Type 2] (Type: String, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: False, Addressable: True)
CurrentPosition [Current Position] (Type: String, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: False, Addressable: True)
BypassValve [Bypass Valve] (Type: Int16, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: True, Addressable: True)
RegulationType [Regulation Type] (Type: Int16, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: True, Addressable: True)
DepthToNut [Depth of Nut] (Type: Double, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: True, Addressable: True)
TurnsToClose [Turns to Close] (Type: String, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: False, Addressable: True)
ClockwiseToClose [Clockwise To Close] (Type: Int16, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: True, Addressable: True)
NormallyOpen [Normally Open] (Type: Int16, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: True, Addressable: True)
PercentOpen [Percent Open] (Type: Int16, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: True, Addressable: True)
GroundType [Ground Type] (Type: String, Visible: True, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: False, Addressable: True)
Shape (Type: Object, Visible: False, Searchable: False, Can Symbolize Unique Value: True, Can Symbolize Class Breaks: True, Addressable: True)